- Clean the accessible filter and remove trapped debris from the drain area.
- Check the drain hose or outlet path for kinks, crushing, or blockages.
- Run a short cycle and confirm the appliance empties fully.
Drain hose kinked/crushed/clogged or sump water frozen (hybrid condensing dryers). On the LG DLHC5502B.ABLEEUS, this code relates to the tumble dryer and should be interpreted together with how the appliance is behaving right now.
- The tumble dryer displays E13 instead of normal status information.
- The current cycle, function, or startup sequence may stop, pause, or behave differently than expected.
- The same code may return after a reset if the underlying issue is still present.
- Drain filter, sump, or outlet path is blocked.
- Drain hose is kinked, crushed, or blocked, or the pump cannot clear the water properly.
- Check whether the fault started after installation or after reconnecting the drain line.
- Make sure the waste connection is open and routed correctly.
- If the code returns after clearing the drain path, the pump or related control circuit may need service.
- Isolate power before reaching into pump or filter areas.
Book service if E13 returns after cleaning the drain path, or if the pump sounds abnormal and the tumble dryer still cannot empty correctly.
Can E13 clear after a reset?
Should I keep using the appliance if it works again briefly?
- Photograph the full display and the product label or rating plate.ExpectedYou can confirm the exact model and avoid support or parts quotes against the wrong product variant.
- Note whether the appliance was idle, starting up, heating, filling, draining, cooling, or finishing a cycle when the code appeared.ExpectedYou have the timing detail that usually matters most in fault triage.
- Write down any recent changes such as a power interruption, filter clean, leak, unusual noise, smell, moved installation, or repeated manual reset attempts.ExpectedSupport can separate a recent event from a longer-running repeat fault faster.
If E13 returns after one clean restart and the user-accessible checks above, treat that as a repeat fault. The safest next move is to compare the model hub, confirm the official manual-safe checks for this device, and then escalate with a clear symptom record instead of opening panels or replacing parts blind.