- Clean the accessible filter and remove trapped debris from the drain area.
- Check the drain hose or outlet path for kinks, crushing, or blockages.
- Run a short cycle and confirm the appliance empties fully.
Drain pump is blocked or the drain hose at the siphon is blocked. On the Siemens WN44A100IN/01, this code relates to the washer-dryer and should be interpreted together with how the appliance is behaving right now.
- The washer-dryer displays E:18 instead of normal status information.
- The current cycle, function, or startup sequence may stop, pause, or behave differently than expected.
- The same code may return after a reset if the underlying issue is still present.
- Drain filter, sump, or outlet path is blocked.
- Drain hose is kinked, crushed, or blocked, or the pump cannot clear the water properly.
- Check whether the fault started after installation or after reconnecting the drain line.
- Make sure the waste connection is open and routed correctly.
- If the code returns after clearing the drain path, the pump or related control circuit may need service.
- Isolate power before reaching into pump or filter areas.
Book service if E:18 returns after cleaning the drain path, or if the pump sounds abnormal and the washer-dryer still cannot empty correctly.